About

EMC measurement and test laboratory

State-accredited test center no. 185 for electromagnetic compatibility

(EN, EN/IEC, CISPR, IEC, ETSI EN, FCC, ANSI)

Learn more

You can find the latest information on convenient travel by public transport under “Information and links”!

About EMC

The electromagnetic compatibility(EMC) of a technical device refers to its ability not to interfere with other devices in its environment through electrical or electromagnetic effects or to be interfered with by other devices in its environment. The correct verification of electromagnetic compatibility is the responsibility of the manufacturer for his product. The declaration of conformity with the EMC Directive entitles a device to be marked with the CE mark. A basis for the declaration of conformity is the EMC test report of an accredited testing body (conformity assessment body)

EMC is tested in special test chambers in which, on the one hand, the electromagnetic radiation (emission) without environmental influences is documented and, on the other hand, the influences of electromagnetic radiation on the functioning of a technical device (interference immunity) are tested under laboratory conditions.

The EMC laboratory has had the most modern test chamber in Austria since 2022. EMC tests are carried out in the 12.7 x 8.2 x 6.4 meter semi-anechoic chamber (SAC 5 m) with a 5-meter measuring section for a frequency range between 9 kHz and 40 GHz. It is the latest facility of the state-accredited EMC measurement and testing laboratory of the Research Association of the Carinthian University of Applied Sciences in Villach.










To the ORF report

Our services

The EMC measurement and testing laboratory in Villach is the state accredited testing laboratory number 185. The test laboratory offers compliance tests for over 60 accredited test standards and guidelines for emission and immunity (immission).

Selection from the scope of accreditation

  • 2014/30/EU EMC directive (CE-sign)
  • IEC/EN 60601-1-2 Medical electrical equipment (EMC)
  • ETSI EN 301489-x according to RED directive 2014/53/EU, article 3.1(b)
  • IEC/EN 50121-x Railway applications (EMC)
  • IEC/EN 62233 EMF tests
    FCC 47 CFR Part 15 / Part 18 (ANSI/IEEE 63.4)

Tests are carried out in the test laboratory in Villach or at the customer’s site (in situ): Household appliances, industrial equipment, e-mobility equipment (including e-bikes, charging stations), automotive components, medical equipment, semiconductor equipment (SEMI) and RED (radio equipment devices), equipment for mining, railroads, aircraft (antenna characteristics). Testing is performed according to international (CISPR, IEC, ETS, ETSI, ISO), European EN standards and North American standards (ANSI, FCC).




Another area is EN/IEC 62233 (EMF) for household applications and their electromagnetic effects on humans (human exposure).

Our customers also make use of measurements accompanying development (precompliance tests) outside the scope of accreditation. A variety of standards are available for this purpose. The largest segment here is testing for electronic subassemblies (EUB) for the automotive sector. Details for Automotive tests can be found here.

As a technical office for consulting engineers, advice can be given regarding the conformity of production, research into standards and assistance with national and international approvals.

The test laboratory also offers EMC training and special seminars as well as laboratory exercises for students.

Under the following link you will find all the services offered by our laboratory:


Download EMC folder

Equipment

The accredited test laboratory in Villach operates a wide range of technical equipment, which is regularly checked by external calibrations and interlaboratory tests for the accredited measurements. In addition to amplifiers for various frequency ranges and field strengths, they are antennas for emission and immunity measurements.

Absorber chambers

In the center of the laboratory are two absorber chambers of the most modern design: a semi-absorber hall (SAC 5 m) from the company Frankonia and a full absorber hall (FAR 3m) from the company Siemens Matsushita. The 6.4-metre high SAC 5 m has a 3.0 x 3.0-metre feed gate with a 3.0-metre diameter turntable that can be loaded with up to 2.5 tons. This means that automotive tests for all electric passenger cars can be carried out in a partially automated manner. The FAR 3m has an insertion port of 1.5 x 2.0 with a maximum measuring distance of 3 meters.


SAC 5 m sliding door (slide door SAC 5 m)

The FAR 3 m (inside the FAR 3 m).

Radiated emissions can be tested according to CISPR, EN, IEC and FCC from 30 MHz to 40 GHz (magnetic fields from 9 kHz to 30 MHz). Conducted emissions are measured in the range between 9 kHz and 30 MHz (300 MHz).


Detail description of the SAC 5 m

Umbrella cabins

In addition to the two absorber chambers, the laboratory has a 5 x 7 x 4 meter shielded cabin (door 3.0 x 2.5 meters) and a 5 x 8 x 3 meter shielded cabin (door 1.5 x 2.1 meters).












The laboratory has

  • Emission measuring stations – CE, RE, IP
  • Measuring stations for interference immunity (e.g. EN 61000-4-4 Burst)
  • Measuring stations for mains reactions (e.g. EN 61000-3-2)
  • Measuring stations for special automotive measurements

Selection from measuring device list:

  • EMC measuring receiver up to 40 GHz
  • RF amplifier up to 6 GHz
  • RF signal generators up to 6 GHz
  • Antennas from 9 kHz to 40 GHz
  • ESD generators up to 30 kV
  • LISNs, DCNs, test heads ….

Standards

The EMC measuring and testing center in Villach tests according to the following guidelines and directives:

  • 2014/30/EU*EMC
    Directive 2014/30/EU of the European parliament and of the council of 26 February 2014 on the harmonization of the laws of the Member States relating to electromagnetic compatibility
  • ILAC-P10
    ILAC Policy on Metrological Traceability of Measurement Results
  • ILAC-P9
    LAC Policy for Participation in Proficiency Testing Activities
  • EA-3/01
    EA Conditions for the use of Accreditation Symbols, Logos and other claims of accreditation and reference to the EA MLA Signatory status (rev05)

List of standards in the scope of accreditation

  • International standards (CISPR, IEC)
  • European standards (EN, ETSI)
  • North American standards (FCC, ANSI)

The standards accredited in Austria can also be found on the homepage of the Federal Ministry of Labor and Economy (in the filter please set the criterion 0185 – see screenshot below):





Download list of standards in the scope of accreditation

Certificates / Accreditation

  • The EMC measurement and testing laboratory in Villach is accredited by the Austrian national accreditation body “Akkreditierung Austria” according to EN ISO/IEC 17025 as testing laboratory no. 185.
  • The Austrian national accreditation body “Akkreditierung Austria” is a full member of the International Laboratory Accreditation Cooperation ILAC and signatory of the MRAs for the areas “Testing, Calibration and Inspection”.

Wappen_EMV-Labor

  • Unintentional Radiators-FCC Part 15, Subpart B 
  • Industrial, Scientific, and Medical Equipment-FCC Part 18
  • Intentional Radiators – FCC Part 15 Subpart C
  • Maximum Assessed Frequency: 40 GHz
  • Test Firm Registration Number: 327605
  • Designation Number: AT0003




Austrolab member no. 118

www.austrolab.at

Activities / Events / Info


Online-Seminar EN ISO/IEC 17025 – Austrian Standards

In der praxisnahen Schulung wurden die wichtigsten Anforderungen an Prüflabore und aktuelle Entwicklungen rund um das Qualitätsmanagement vermittelt. Durch den intensiven Austausch […]

>> read more

EMV Fachtagung 2025

Die EMV-Fachtagung ist seit vielen Jahren ein fixer Bestandteil im Kalender der EMV-Community. Heuer fand die Veranstaltung bereits zum 22. Mal statt […]

>> read more

Ausbildung zum EMV-Prüfer abgeschlossen

07/2025 – Wir gratulieren Lucas Pucher zur abgeschlossenen Ausbildung als EMV-Prüfer!

>> read more

21.05.2025 – EMV Seminar

Am 21. Mai 2025 fand in unserem EMV-Labor ein EMV-Seminar statt, das wir gemeinsam mit den Firmen Würth Elektronik Austria, Rohde & […]

>> read more

EMV Vortrag HTL Mössingerstraße

Am Freitag, den 04.04.2025, begab sich unser Prüfzentrumsleiter Michael Reil auf den Weg nach Klagenfurt in die HTL Mössingerstraße, um einen EMV […]

>> read more

Exkursion der 5.Klasse der HTL Mössingerstraße ins EMV Labor

>> read more

EMV Vorlesung

Im Wintersemester 24 fand im Zuge des Studiums „Systems Engineering“ die EMV Vorlesung für Student*innen des 5.Semensters mit Schwerpunkt Elektronik statt. Unter […]

>> read more

Vorlesungseinheit der Firma Würth Elektronik

Auch heuer wieder durften sich die Studenten des 5.Semesters des Studiengangs Systems Engineering mit dem Schwerpunkt Elektronik einen Gastvortrag der Firma Würth […]

>> read more

Kundeninformation

Quelle: CE-Newsletter Ausgebe Nr. 07/2024

>> read more

Wir gratulieren zur mit Auszeichnung bestandenen Masterprüfung!

Titel der Masterarbeit:
„Development of a comb generator as reference source for radiated emission measurements above 1 GHz“

>> read more

e&i Science News – Beitrag zum EMV-Labor

in der Ausgabe 2.2024  (e&i ÖVE Fachzeitschrift)

>> read more

12.04.2024 Führung HTL Mössingerstraße, Klagenfurt

Am 12.04.2024 hatten wir Besuch von der „Systems Engineering“ Gruppe der 5.Jahrgänge der HTL Mössingerstraße.

>> read more

FCC Akkreditierung

Um Zugang zum US-amerikanischen Markt zu erhalten und dort erfolgreich zu sein, müssen Hersteller von Telekommunikationsgeräten Konformitätsvorschriften einhalten, welche von der Federal Communications Commission (FCC) herausgegeben werden.

>> read more

EMV 2024

Die EMV Messe ist ein jährlicher Fixpunkt für die EMV Community.

>> read more

Gastvortrag der Firma Würth Elektronik

Im Zuge der EMV – Vorlesung durften sich die Studenten des 5.Semesters des Studiengangs Systems Engineering mit Schwerpunkt Elektronik einen Gastvortrag der Firma Würth Elektronik anhören.

>> read more

Holzbaupreis 2023

Unser neues EMV-Labor erhielt von proHolz Kärnten eine Anerkennung im Zuge des Holzbaupreises 2023.

>> read more

27.09.2023 & 28.09.2023 Weiterbildung – EMV Fachtagung 

Die EMV Fachtagung hat sich mittlerweile zu einem jährlichen Fixpunkt für den Erfahrungs- und Gedankenaustausch innerhalb der EMV-Community entwickelt.

>> read more

21.09.2023 Tag der offenen Tür 

Am 21.09.2023 fand im EMV Mess- und Prüflabor ein Tag der offenen Tür statt.

>> read more

04.07.2023 Würth Seminar

Am 04.07.2023 fand bei uns im EMV Labor, gemeinsam mit den Firmen Würth Elektronik Austria und Rohde & Schwarz, ein EMV Seminar statt.

>> read more

11.04.2023 Führung/ Exkursion HTL Mössingerstraße, Klagenfurt

Am 11.04.2023 hatte die „Systems Engineering“ Gruppe der 5.Jahrgänge der HTL Mössingerstraße die Gelegenheit, an einer Exkursion in unser EMV Labor teilzunehmen.

>> read more
Show all news

Team

DI Herbert Kotschnig
Managing Director
h.kotschnig@fh-kaernten.at

DI(FH) Michael Reil
Test center manager/EMC inspector
m.reil@fh-kaernten.at

DI Harald Perschak
Quality assurance manager/EMC auditor
h.perschak@fh-kaernten.at

Engineer Mario Janschitz
Laboratory engineer/EMC tester (retired)
m.janschitz@fh-kaernten.at

Lucas Pucher
Laboratory assistant/EMC tester
l.pucher@fh-kaernten.at

Engineer Fabian Gärtner, BSc, MSc
Laboratory engineer/EMC tester
f.gaertner@fh-kaernten.at

Julia Daross
Accounting
j.daross@fh-kaernten.at

Contact

Research Society of the FH Kärnten mbH

EMC measurement and testing laboratory
State-accredited testing laboratory no. 185

Europastrasse 3a (entrance B)
A-9524 Villach

+43 5 90500 2644
emv@fh-kaernten.at

Information and links

With the new Koralm Railway, you only need one hour and five minutes from Graz main station to Villach main station. The journey from Vienna main station only takes about 3 hours and 30 minutes. From Villach main station, you can take bus lines 3 or 8 directly to the EMV laboratory. Detailed information is available via the links below.

Accommodation (hotels) nearby:


Hotel Seven


B&B Hotel


Hotel City

Left:


FH Carinthia


ÖBB train connection


Westbahn train connection


Bus connection Villach main station – EMV Labor

Info:



EMC Conversion Formulas