{"id":6887,"date":"2021-06-11T07:20:52","date_gmt":"2021-06-11T06:20:52","guid":{"rendered":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/2021\/06\/11\/homematic-actuator-quick-repair-dimming-actuator-rs485\/"},"modified":"2021-06-11T07:20:52","modified_gmt":"2021-06-11T06:20:52","slug":"homematic-actuator-quick-repair-dimming-actuator-rs485","status":"publish","type":"post","link":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/2021\/06\/11\/homematic-actuator-quick-repair-dimming-actuator-rs485\/?lang=en","title":{"rendered":"Homematic actuator quick repair (dimming actuator RS485)"},"content":{"rendered":"<div class=\"pvc_clear\"><\/div>\n<p id=\"pvc_stats_6887\" class=\"pvc_stats all  \" data-element-id=\"6887\" style=\"\"><i class=\"pvc-stats-icon medium\" aria-hidden=\"true\"><svg aria-hidden=\"true\" focusable=\"false\" data-prefix=\"far\" data-icon=\"chart-bar\" role=\"img\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\" class=\"svg-inline--fa fa-chart-bar fa-w-16 fa-2x\"><path fill=\"currentColor\" d=\"M396.8 352h22.4c6.4 0 12.8-6.4 12.8-12.8V108.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v230.4c0 6.4 6.4 12.8 12.8 12.8zm-192 0h22.4c6.4 0 12.8-6.4 12.8-12.8V140.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v198.4c0 6.4 6.4 12.8 12.8 12.8zm96 0h22.4c6.4 0 12.8-6.4 12.8-12.8V204.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v134.4c0 6.4 6.4 12.8 12.8 12.8zM496 400H48V80c0-8.84-7.16-16-16-16H16C7.16 64 0 71.16 0 80v336c0 17.67 14.33 32 32 32h464c8.84 0 16-7.16 16-16v-16c0-8.84-7.16-16-16-16zm-387.2-48h22.4c6.4 0 12.8-6.4 12.8-12.8v-70.4c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v70.4c0 6.4 6.4 12.8 12.8 12.8z\" class=\"\"><\/path><\/svg><\/i> <img decoding=\"async\" width=\"16\" height=\"16\" alt=\"Loading\" src=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-content\/plugins\/page-views-count\/ajax-loader-2x.gif\" border=0 \/><\/p>\n<div class=\"pvc_clear\"><\/div>\n<p style=\"text-align: justify\"><a href=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor00-e1583328754232.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-4783 alignleft\" src=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor00-e1583328754232-271x300.jpg\" alt=\"\" width=\"271\" height=\"300\" srcset=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor00-e1583328754232-271x300.jpg 271w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor00-e1583328754232.jpg 760w\" sizes=\"(max-width: 271px) 100vw, 271px\" \/><\/a>I have another small contribution to make on the subject of &#8222;Aging and Homematic Smart Home&#8220;. Many thanks to Fritz for the preparation and analysis.<\/p>\n<p style=\"text-align: justify\">As in the last post &#8222;Homematic actuator quick repair&#8220;, this time it is again about a device from the Smart Home series. It is the dimmer actuator with the designation &#8222;HMW-LC-Dim1L-DR&#8220;. This is a phase control dimmer actuator for incandescent lamps and low-voltage halogen lamps with conventional transformers. Many modern LED lamps can also be controlled with this dimmer. The actuator belongs to the &#8222;wired&#8220; series, which means that it is not connected to the CCU via the BidCos radio protocol, but via the RS485 bus. The actuator receives the power supply for data communication from a 24V power supply unit. This also supplies the \u00b5C in the actuator. The network side is supplied with control data from the low-voltage side via an optocoupler. This ensures galvanic isolation. On the network side there is a dimmer controller module, which in turn controls the triac. This controller must be supplied with a voltage of approx. 15V. To generate this, the manufacturer has built in a capacitive voltage divider. And this is where the aging problems begin &#8230;<\/p>\n<p style=\"text-align: justify\">The error pattern manifests itself as follows: The connected light source cannot be dimmed or switched on. However, the dimmer is communicating correctly with the bus. The red function LED lights up correctly. The commands for &#8222;Off&#8220; and &#8222;On&#8220; via buttons are also displayed in the CCU.<\/p>\n<div id=\"attachment_4793\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/HMW-LC-Dim1L-DR.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-4793\" class=\"wp-image-4793 size-medium\" src=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/HMW-LC-Dim1L-DR-300x207.jpg\" alt=\"\" width=\"300\" height=\"207\" srcset=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/HMW-LC-Dim1L-DR-300x207.jpg 300w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/HMW-LC-Dim1L-DR-1024x706.jpg 1024w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/HMW-LC-Dim1L-DR-768x529.jpg 768w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/HMW-LC-Dim1L-DR-1536x1059.jpg 1536w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/HMW-LC-Dim1L-DR-2048x1411.jpg 2048w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4793\" class=\"wp-caption-text\">Circuit diagram of the mains side on the &#8222;main board&#8220;<\/p><\/div>\n<div id=\"attachment_4786\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor03-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4786\" class=\"wp-image-4786 size-medium\" src=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor03-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor03-300x225.jpg 300w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor03-1024x768.jpg 1024w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor03-768x576.jpg 768w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor03-1536x1152.jpg 1536w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor03-2048x1536.jpg 2048w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4786\" class=\"wp-caption-text\">defective 330nF X2 capacitor<\/p><\/div>\n<p style=\"text-align: justify\">The cause: According to the data sheet, the IC U2008, a dimmer control module, is supplied with a voltage of DC 15V. In this case, the supply voltage was significantly lower (at approx. 5.8V). This supply voltage is made the 330nF \/ 275V X2 capacitor C4. The capacitor is optically in perfect condition, but a simple capacitance measurement quickly shows that nothing fits here. The capacitor C4 only had a capacity of approx. 30-40nF. So it&#8217;s like so often -&gt; It was the capacitor: D<\/p>\n<div id=\"attachment_4784\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor01-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4784\" class=\"wp-image-4784 size-medium\" src=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor01-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor01-300x225.jpg 300w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor01-1024x768.jpg 1024w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor01-768x576.jpg 768w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor01-1536x1152.jpg 1536w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor01-2048x1536.jpg 2048w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4784\" class=\"wp-caption-text\">Dimmer module side view<\/p><\/div>\n<p style=\"text-align: justify\">After the replacement, the voltage on the U2008 was ok again and the dimmer is doing its job again. As a preventive measure, the two other X2 capacitors on the board (C1 47nF \/ 275V and C2 100nF \/ 275) were replaced.<\/p>\n<div id=\"attachment_4785\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor02-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4785\" class=\"wp-image-4785 size-medium\" src=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor02-scaled-e1583328924589-300x169.jpg\" alt=\"\" width=\"300\" height=\"169\" srcset=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor02-scaled-e1583328924589-300x169.jpg 300w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor02-scaled-e1583328924589-1024x576.jpg 1024w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor02-scaled-e1583328924589-768x432.jpg 768w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor02-scaled-e1583328924589-1536x864.jpg 1536w, https:\/\/blog.fh-kaernten.at\/ingmarsretro\/files\/2020\/03\/aktor02-scaled-e1583328924589-2048x1151.jpg 2048w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4785\" class=\"wp-caption-text\">Installation locations of C1 and C2<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"pvc_clear\"><\/div>\n<p id=\"pvc_stats_6887\" class=\"pvc_stats all  \" data-element-id=\"6887\" style=\"\"><i class=\"pvc-stats-icon medium\" aria-hidden=\"true\"><svg aria-hidden=\"true\" focusable=\"false\" data-prefix=\"far\" data-icon=\"chart-bar\" role=\"img\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\" class=\"svg-inline--fa fa-chart-bar fa-w-16 fa-2x\"><path fill=\"currentColor\" d=\"M396.8 352h22.4c6.4 0 12.8-6.4 12.8-12.8V108.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v230.4c0 6.4 6.4 12.8 12.8 12.8zm-192 0h22.4c6.4 0 12.8-6.4 12.8-12.8V140.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v198.4c0 6.4 6.4 12.8 12.8 12.8zm96 0h22.4c6.4 0 12.8-6.4 12.8-12.8V204.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v134.4c0 6.4 6.4 12.8 12.8 12.8zM496 400H48V80c0-8.84-7.16-16-16-16H16C7.16 64 0 71.16 0 80v336c0 17.67 14.33 32 32 32h464c8.84 0 16-7.16 16-16v-16c0-8.84-7.16-16-16-16zm-387.2-48h22.4c6.4 0 12.8-6.4 12.8-12.8v-70.4c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v70.4c0 6.4 6.4 12.8 12.8 12.8z\" class=\"\"><\/path><\/svg><\/i> <img decoding=\"async\" width=\"16\" height=\"16\" alt=\"Loading\" src=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-content\/plugins\/page-views-count\/ajax-loader-2x.gif\" border=0 \/><\/p>\n<div class=\"pvc_clear\"><\/div>\n<p>I have another small contribution to make on the subject of &#8222;Aging and Homematic Smart Home&#8220;. Many thanks to Fritz for the preparation and analysis. As in the last post &#8222;Homematic actuator quick repair&#8220;, this time it is again about a device from the Smart Home series. It is the dimmer actuator with the designation&hellip; <br \/> <a class=\"read-more\" href=\"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/2021\/06\/11\/homematic-actuator-quick-repair-dimming-actuator-rs485\/?lang=en\">Weiterlesen<\/a><\/p>\n","protected":false},"author":86,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"ngg_post_thumbnail":0,"footnotes":""},"categories":[1499,1620],"tags":[2105,2109,2106,2110,2104,2108,2107,2111],"class_list":["post-6887","post","type-post","status-publish","format-standard","hentry","category-miscellaneous","category-repair-and-restauration","tag-dimming-actuator","tag-eq3-repair","tag-hm-lc-dim1t-fm-en","tag-hmw-lc-dim1l-dr-en","tag-homematic-en","tag-homematic-blinking","tag-rapair-homematic","tag-rs485-dimming-actuator"],"a3_pvc":{"activated":true,"total_views":55,"today_views":0},"_links":{"self":[{"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/posts\/6887","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/users\/86"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/comments?post=6887"}],"version-history":[{"count":0,"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/posts\/6887\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/media?parent=6887"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/categories?post=6887"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.fh-kaernten.at\/ingmarsretro\/wp-json\/wp\/v2\/tags?post=6887"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}