{"id":14,"date":"2018-01-11T10:00:05","date_gmt":"2018-01-11T09:00:05","guid":{"rendered":"http:\/\/blog.fh-kaernten.at\/emv\/?page_id=14"},"modified":"2018-01-11T10:00:05","modified_gmt":"2018-01-11T09:00:05","slug":"labor","status":"publish","type":"page","link":"https:\/\/blog.fh-kaernten.at\/emv\/labor\/","title":{"rendered":"Labor"},"content":{"rendered":"<p><strong>Emission<\/strong><\/p>\n<table dir=\"\" summary=\"\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">Absorberhalle<\/td>\n<td valign=\"top\">4 m x 7 m x 4 m<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Schirmkabine<\/td>\n<td valign=\"top\">5 m x 7 m x 4 m<br \/>\n(Kabinent\u00fcr 3 m x 2.5 m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Abgestrahlte<br \/>\nHF-Felder<\/td>\n<td valign=\"top\">30 MHz &#8211; 7,0 GHz<br \/>\n(H-Feld 9 kHz &#8211; 30 MHz)<br \/>\ngem\u00e4\u00df EN 55022, EN 55011, EN 55015<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>Frequenzbereichserweiterung: 7 GHz<\/strong><\/h3>\n<div class=\"align-right\">\n<table class=\"align-left\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td class=\"align-left\" valign=\"top\">Leitungsgebundene<br \/>\nSt\u00f6rungen<\/td>\n<td class=\"align-left\" valign=\"top\">9 kHz &#8211; 30 MHz (300 MHz)<br \/>\ngem\u00e4\u00df EN 55022, EN 55011,<br \/>\nEN 55014-1, EN 55015<\/td>\n<\/tr>\n<tr>\n<td class=\"align-left\" colspan=\"2\" valign=\"top\">Niederspannungsnetze<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">EN 61000-3-2<br \/>\nOberschwingungsstr\u00f6me<\/td>\n<td valign=\"top\">EN 61000-3-3<br \/>\nSpannungsschwankungen, Flicker<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"csc-default\">\n<strong>St\u00f6rfestigkeit<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>EN 61000-4-2<\/td>\n<td>Entladungen statischer Elektrizit\u00e4t (ESD), bis 30 kV<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>EN 61000-4-3<\/strong><\/td>\n<td><strong>Eingestrahlte HF-Felder,<br \/>\n80 MHz bis 4 GHz, bis 40 V\/m<br \/>\n<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">EN 61000-4-4<\/td>\n<td>Schnelle transiente elektrische St\u00f6rgr\u00f6\u00dfen (BURST),<br \/>\nbis 4,5 kV<\/td>\n<\/tr>\n<tr>\n<td>EN 61000-4-5<\/td>\n<td>Sto\u00dfspannungen (SURGE),bis 4,5 kV<\/td>\n<\/tr>\n<tr>\n<td>EN 61000-4-6<\/td>\n<td>Leitungsgef\u00fchrte St\u00f6rgr\u00f6\u00dfen,bis 50 V<\/td>\n<\/tr>\n<tr>\n<td>EN 61000-4-8<\/td>\n<td>Netzfrequente Magnetfelder,bis 300 A\/m<\/td>\n<\/tr>\n<tr>\n<td>EN 61000-4-9<\/td>\n<td>Impulsf\u00f6rmige Magnetfelder,bis 1000 A\/m<\/td>\n<\/tr>\n<tr>\n<td>EN 61000-4-11<\/td>\n<td>Spannungseinbr\u00fcche, -unterbrechungenu. -schwankungen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"csc-default\">\n<h3><strong>Messequipment<\/strong><\/h3>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\"><strong>Mikrosekunden Generator f\u00fcr ISO Pulse 1, 1a, 2 und 6<\/strong><br \/>\nPr\u00fcfspannung bis 600 V, Koppelstrecke ACC,\u00a0\u00a0ISO 7637 \/ DIN 40839<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Mikrosekunden Generator f\u00fcr ISO Pulse 1, 1a, 2 und 6<\/strong><br \/>\nPr\u00fcfspannung bis 1500 V, Koppelstrecke ACC, \u00a0ISO 7637 \/ DIN 40839<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Load Dump Generator f\u00fcr ISO Pulse 5 und 7<\/strong><br \/>\nPr\u00fcfspannung bis 200 V, ISO 7637 \/ DIN 40839<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Voltage Drop Simulator f\u00fcr ISO Pulse 2b und 4, Jaso-Test 1, 2<\/strong><br \/>\nPr\u00fcfspannung bis 30 V, \u00a0ISO 7637 \/ DIN 40839, \u00a0Jump-Start Impuls, Netzausfall, u.v.m<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Strip-Line<\/strong><br \/>\n(Feldst\u00e4rken bis 400V\/m Frequenzbereich bis 1GHz)<br \/>\n<strong>TEM-Zelle<\/strong><br \/>\n(Feldst\u00e4rken bis 400V\/m Frequenzbereich bis 400MHz)<br \/>\n<strong>BCI Stromzange bis 150dB\u00b5A<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Emission Absorberhalle 4 m x 7 m x 4 m Schirmkabine 5 m x 7 m x 4 m (Kabinent\u00fcr 3 m [&hellip;]<\/p>\n","protected":false},"author":48,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"class_list":["post-14","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Labor - EMV \u2013 Mess- und Pr\u00fcflabor<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.fh-kaernten.at\/emv\/labor\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Labor - EMV \u2013 Mess- und Pr\u00fcflabor\" \/>\n<meta property=\"og:description\" content=\"Emission Absorberhalle 4 m x 7 m x 4 m Schirmkabine 5 m x 7 m x 4 m (Kabinent\u00fcr 3 m [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.fh-kaernten.at\/emv\/labor\/\" \/>\n<meta property=\"og:site_name\" content=\"EMV \u2013 Mess- und Pr\u00fcflabor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/labor\\\/\",\"url\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/labor\\\/\",\"name\":\"Labor - EMV \u2013 Mess- und Pr\u00fcflabor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/#website\"},\"datePublished\":\"2018-01-11T09:00:05+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/labor\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/labor\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/labor\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Labor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/#website\",\"url\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/\",\"name\":\"EMV \u2013 Mess- und Pr\u00fcflabor\",\"description\":\"Europastra\u00dfe 3a, A-9524 Villach\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.fh-kaernten.at\\\/emv\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Labor - EMV \u2013 Mess- und Pr\u00fcflabor","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.fh-kaernten.at\/emv\/labor\/","og_locale":"de_DE","og_type":"article","og_title":"Labor - EMV \u2013 Mess- und Pr\u00fcflabor","og_description":"Emission Absorberhalle 4 m x 7 m x 4 m Schirmkabine 5 m x 7 m x 4 m (Kabinent\u00fcr 3 m [&hellip;]","og_url":"https:\/\/blog.fh-kaernten.at\/emv\/labor\/","og_site_name":"EMV \u2013 Mess- und Pr\u00fcflabor","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/blog.fh-kaernten.at\/emv\/labor\/","url":"https:\/\/blog.fh-kaernten.at\/emv\/labor\/","name":"Labor - EMV \u2013 Mess- und Pr\u00fcflabor","isPartOf":{"@id":"https:\/\/blog.fh-kaernten.at\/emv\/#website"},"datePublished":"2018-01-11T09:00:05+00:00","breadcrumb":{"@id":"https:\/\/blog.fh-kaernten.at\/emv\/labor\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.fh-kaernten.at\/emv\/labor\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/blog.fh-kaernten.at\/emv\/labor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/blog.fh-kaernten.at\/emv\/"},{"@type":"ListItem","position":2,"name":"Labor"}]},{"@type":"WebSite","@id":"https:\/\/blog.fh-kaernten.at\/emv\/#website","url":"https:\/\/blog.fh-kaernten.at\/emv\/","name":"EMV \u2013 Mess- und Pr\u00fcflabor","description":"Europastra\u00dfe 3a, A-9524 Villach","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.fh-kaernten.at\/emv\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"}]}},"_links":{"self":[{"href":"https:\/\/blog.fh-kaernten.at\/emv\/wp-json\/wp\/v2\/pages\/14","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.fh-kaernten.at\/emv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/blog.fh-kaernten.at\/emv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/blog.fh-kaernten.at\/emv\/wp-json\/wp\/v2\/users\/48"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.fh-kaernten.at\/emv\/wp-json\/wp\/v2\/comments?post=14"}],"version-history":[{"count":0,"href":"https:\/\/blog.fh-kaernten.at\/emv\/wp-json\/wp\/v2\/pages\/14\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.fh-kaernten.at\/emv\/wp-json\/wp\/v2\/media?parent=14"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}